ABB MAGNETIC CONTACTORS AX50AX65AX80

ABB MAGNETIC CONTACTORAX50...AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.DimensionsLargura Líquida do Produto: 82 mmProfundidade/Comprimento Líquidos do Produto: 110 mmAltura Líquida do Produto: 108 mmPeso Líquido do Produto: 1.05 kgTechnicalNumber of Main Contacts NO:3Number of Main Contacts NC:0Number of Auxiliary Contacts NO:1Number of Auxiliary Contacts NC:1Tensão operacional nominal:Auxiliary Circuit 690 VMain Circuit 690 VFrequência nominal (f):Auxiliary Circuit 50 / 60 HzMain Circuit 50 / 60 HzConventional Free-air Thermal Current (Ith):acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 100 ARated Operational Current AC-1 (Ie):(220 / 240 V) 55 °C 85 A(690 V) 40 °C 100 A(690 V) 70 °C 70 ARated Operational Current AC-3 (Ie):(415 V) 55 °C 50 A(440 V) 55 °C 45 A(500 V) 55 °C 45 A(690 V) 55 °C 35 A(380 / 400 V) 55 °C 50 A(220 / 230 / 240 V) 55 °C 53 ARated Operational Power AC-3 (Pe):(415 V) 25 kW(440 V) 25 kW(500 V) 30 kW(690 V) 30 kW(380 / 400 V) 22 kW(220 / 230 / 240 V) 15 kWRated Short-time Withstand Current Low Voltage (Icw):at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 AMaximum Breaking Capacity:cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 ARated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 VRated Impulse Withstand Voltage (Uimp): Auxiliary Circuit 6 kVMaximum Electrical Switching Frequency:(AC-1) 600 cycles per hour(AC-3) 600 cycles per hourMaximum Mechanical Switching Frequency: 3600 cycles per hourRated Control Circuit Voltage (Uc):50 Hz 200 V60 Hz 200 ... 220 VPower Loss:at Rated Operating Conditions AC-1 per Pole 5 Wat Rated Operating Conditions AC-3 per Pole 1.3 WOperate Time:Between Coil De-energization and NC Contact Closing 7 ... 14 msBetween Coil De-energization and NO Contact Opening 4 ... 11 msBetween Coil Energization and NC Contact Opening 7 ... 22 msBetween Coil Energization and NO Contact Closing 8 ... 27 msGrau de proteção:acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20Binário de aperto:Control Circuit 1 N·mMain Circuit 4 N·mTipo de terminal: Screw TerminalsNome de Produto: Block ContactorTechnical UL/CSAGeneral Use Rating UL/CSA:(600 V AC) 80 AClassificação de potência UL/CSA:(120 V AC) Single Phase 3 hp(200 ... 208 V AC) Three Phase 15 hp(220 ... 240 V AC) Three Phase 20 hp(240 V AC) Single Phase 10 hp(440 ... 480 V AC) Three Phase 40 hp(550 ... 600 V AC) Three Phase 50 hpTightening Torque UL/CSA:Auxiliary Circuit 9 in·lbControl Circuit 9 in·lbMain Circuit 35 in·lbFull Load Amps Motor Use:(120 V AC) Single Phase 34 A(200 ... 208 V AC) Three Phase 48.3 A(220 ... 240 V AC) Three Phase 54 A(240 V AC) Single Phase 50 A(440 ... 480 V AC) Three Phase 52 A(550 ... 600 V AC) Three Phase 52 AEnvironmentalTemperatura do ar ambiente:Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °CClose to Contactor without Thermal O/L Relay -40 ... 70 °CClose to Contactor for Storage -60 ... +80 °CNear Contactor for Operation in Free Air -40 ... 70 °CClimatic Withstand:acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification IIAltitude de operação máxima permissível:Without Derating 3000 mMaterial ComplianceConflict Minerals Reporting Template (CMRT):CMRT - Conflict Minerals Reporting TemplateREACH Declaration:REACH - Letter of Confirmation for block contactors, contactor relays, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessoriesInformação RoHS:RoHS II declaration for block contactors, installation contactors, mini contactors, mini contactor relays, thermal overload relays, electronic overload relays and related accessoriesEstado RoHS:Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019Toxic Substances Control Act - TSCA:Toxic Substances Control Act (TSCA) declaration for ContactorsREEE B2C / B2B:Business To BusinessCategoria REEE:5. Small Equipment (No External Dimension More Than 50 cm)Certificates and DeclarationsCB Certificate:AX 50~80A CB certificationCCC Certificate:9AKK107492A7091CCS Certificate:CCS Certificate of AFC09 ... AFC96 , AX09-AX370 contactorsCQC Certificate:CQC Certificate, Contactor, AX50, AX65, AX80, Made in ChinaDeclaration of Conformity - CCC:CCC Declaration of Conformity, Contactor, AX50, AX65, AX80, Made in ChinaDeclaração de conformidade -CE:EU Declaration of Conformity AX06, AX09, AX12, AX18, AX25, AX32, AX40, AX50, AX65, AX80 3-pole ContactorsCertificado UL:UL Certificate of Compliance – AX06, AX09, AX12, AX18, AX25Container InformationUnidades de embalagem Nível 1: box 1 pieceLargura da embalagem Nível 1:102 mmProfundidade/Comprimento da embalagem Nível 1:143 mmAltura da embalagem Nível 1: 152 mmPeso bruto da embalagem Nível 1: 1.16 kgNível de Embalagem 1 EAN: 3471522404756External Classifications and StandardsCódigo de classificação do objeto:QETIM 7: EC000066 - Power contactor, AC switchingETIM 8: EC000066 - Power contactor, AC switchingETIM 9: EC000066 - Power contactor, AC switchingeClass: V11.0 : 27371003UNSPSC: 39121529Código de Categoria Granular IDEA (IGCC): 4755 >> Contactors

ABB Philippines

ABB Philippines

Seller ratings 100%

Review

Oops
This video has no reviews.